Refrigerant Circle 500L Split Heat Pump Water Heater For Villa Restaurant

Brand Name : Shenglin

Model Number : KF series

Certification : CE

Place of Origin : China

MOQ : 1 pcs

Payment Terms : T/T, Western Union

Supply Ability : 1000 PCS/month

Delivery Time : 18~25 days

Packaging Details : Plywood case

Compressor : Mitsubishi or Panasonic Rotary type compressor

Air side heat exchanger type : Finned heat exchanger

Supply power : 220V 1N~50Hz

Refrigerant : R22, R407C and R410A

Working ambient temperature : -15~+43℃

Water outlet temp. : 55~60° C

Heating capacity : 3.7~7.2kW

Application : Ordinary family, villa, office and restaurant and hotel, 24 hours apply shower or washing hands

COP : 4.5

Contact Now

Refrigerant Circle Split Water Heater Heat Pump

Description:

The refrigerant circle domestic split heat pump adopts refrigerant circle the water tank to heat water, outdoor and indoor split design, no water system outside, any freezing and damage to water system. The compact design with small dimension makes the heat pump convenient to be delivered, stored and installed at any space. Widely application place: ordinary family, villa, office and restaurant and hotel, 24 hours apply shower or washing hands.

Features:

Fresh water heating at temperature up to 60℃.
Mitsubishi or Panasonic Rotary type compressor, low vibration, low noise and high reliability.
Multifunction LCD wired controller.
High efficiency up to COP 4.5, saving 75% energy compare to tradition electric heater.
Automatically defrosting.
Simple installation: rooftop, balcony, yard, or basement can be suitable places for the installation.
Durable, long life span up to 15 years, extremely low maintenance cost.
Heating capacity:3.7kW~7.2kW. Tank volume: 150L-500L.
Working temperature range of outdoor -15℃ to 43℃.

Optional:

Galvanized metal cabinet or stainless steel cabinet.
Refrigerant: R22, R407C and R410A is available
Working tank volume options:150/200/250/300/400/500L.

Technical paramater:

Refrigerant circle split water heater series
MODEL KF80-NW KF120-NW KF160-NW
Working temp. range -15~43 -15~43 -15~43
Rated heating capacity KW 3.7 5.5 7.2
Hot water water output L/h 80 120 160
COP W/W 4 4 4
Heating input power KW 0.93 1.38 1.80
Maximum current A 5.75 7.1 9.5
Power supply / 1N~/50Hz/220V
IP code / IPX4
Safety function / High and low pressure protection, Overload protection, Temperature protection
Refrigerant type/weight --/kg R407c/1.15 R407c/1.15 R407c/1.23
Compressor QTY PCS 1
Compressor type / 1
Maximum outlet temp. 60
Noise dB(A) 32 34 48
Dimension (W×D×H) MM 920×335×585 920×335×585 840×310×730
Connecting pipe spec. Inch 1/4", 3/8" 1/4", 3/8" 1/4", 3/8"
Net weight Kg 41 54 58
Packing weight Kg 50 65 68
Inlet and outlet pipe interface Inch G 5/8" Internal thread G 5/8" Internal thread G 5/8"Internal thread
Safety valve specification MPa 1.2 1.2 1.2
Water tank volume L 150L / 200L 150L / 250L / 300L 300L / 400L / 500L
Remarks:
1. Test conditions: (DB/WB) 20°C/15°C, inlet water temperature 15°C, outlet water temperature 55°C.
2. Due to product improvement, above data are subject to change without prior notice, please take the nameplate on the heat pump as standard.

Packing:

Refrigerant Circle 500L Split Heat Pump Water Heater For Villa Restaurant Refrigerant Circle 500L Split Heat Pump Water Heater For Villa Restaurant


Reference:

Country: Taiwan,China, middle school
Model: KFXR-018 UII,KFXR-045UII
Application: Domestic hot water
Country: Taiwan,China,residential building
Model: KFXR-036UII,KFXR-900UII
Application: Domestic hot water
Refrigerant Circle 500L Split Heat Pump Water Heater For Villa RestaurantRefrigerant Circle 500L Split Heat Pump Water Heater For Villa Restaurant Refrigerant Circle 500L Split Heat Pump Water Heater For Villa RestaurantRefrigerant Circle 500L Split Heat Pump Water Heater For Villa Restaurant
Country: Beijing, China
Model: KFXF-180 UII
Application: Breeding heating
Country: Yunan, China
Model: /
Application: Aloe drying
Refrigerant Circle 500L Split Heat Pump Water Heater For Villa RestaurantRefrigerant Circle 500L Split Heat Pump Water Heater For Villa Restaurant Refrigerant Circle 500L Split Heat Pump Water Heater For Villa RestaurantRefrigerant Circle 500L Split Heat Pump Water Heater For Villa Restaurant




Product Tags:

COP 4.5 split heat pump water heater

      

500L split heat pump water heater

      

500L split system water heater

      
Quality Refrigerant Circle 500L Split Heat Pump Water Heater For Villa Restaurant for sale

Refrigerant Circle 500L Split Heat Pump Water Heater For Villa Restaurant Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai Shenglin M&E Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)